MineTrax Ethernet Gateway

Model Number: MTX-EGW-200

Highlights:

  • RS-232 connection with a MineTrax Network Infrastructure Node
  • RS-422 connection with a MineTrax Post-Accident Network Probe (option)
  • TCP/IP/Ethernet connection with MineTrax Central Server

Communications

  • Packets received on RS-232 port from MineTrax Network Infrastructure Node are forwarded on Ethernet port to Central Server
  • Packets received on RS-422 port from MineTrax Post-Accident Network Probe are forwarded on Ethernet port to Central Server
  • Packets received on Ethernet port from Central Server are forwarded on RS-232 port to MineTrax Node for routing to destination node

Power Supply

  • Electrical interface: 5 VDC regulated power (110-240 VAC / 5 VDC power adapter and cable included)
  • Energy consumption: 400 mA @ 5 VDC typical

Physical Characteristics

  • Operating temperature: -40ºC to +70ºC
  • Weatherproofing: IP65
  • Dimensions: 180 mm x 120 mm x 60 mm + Connectors/Cables